- UV germicidal lamp
- Amalgam Lamps
- Standard Output Germicidal Lamps
- Preheat Start Germicidal Lamps-T5 4P
- Preheat Start Germicidal Lamps-T5 2P
- Instant Start (Slimline) Germicidal Lamps-T5 SP
- Preheat Start Germicidal Lamps-T8 2P
- UV Germicidal lamp T6 2P
- UV Germicidal lamp T4 2P
- Compact Germicidal Lamps
- H shape germicidal lamp
- U shape germicidal lamp
- High Output (HO) Germicidal Lamps
- Self-ballast Germicidal Bulbs
- Cold Cathode Germicidal Lamps
- Quartz Sleeves
- UV Air Cleaners
- Electronic Ballasts
- Stainless Steel UV Sterilizers
- Submergible UV Modules
- Mobile UV Disinfection Cart
- UV Table light
- UV Recirculator
- UV Purifier
- Specific Bases and Fittings
- Details
- Technical Data
lDimensions
lWiring diagrams
PH8-800-155
1*Lamp Type: GPH1554T5HO GHO64T5L TUV64T5HO
Wiring Diag:A
2*Lamp Type:GPH846T5HO GPH893T5HO GHO36T5L TUV36T5HO TUV55WHO TUV75WHO
Wiring Diag:B
PH8-1200-190
1*Lamp Type: GPHA1000T5 GPHA1554T5
Wiring Diag:A
2*Lamp Type: GPHA843T5 GPHA357T5
Wiring Diag:B
PH8-1500-150
1*Lamp Type:NNI120/79 NNI120/80 NNI120/84 NIQ120/80 NIQ120/84 TUV115WVHO
Wiring Diag:A
2*Lamp Type: NNI80/36U NIQ75/34 UVL80W/T5
Wiring Diag:B
PH8-1800-150
1*Lamp Type:GPHA843T6 GPHA1000T6
Wiring Diag:A
2*Lamp Type:GPHA357T6
Wiring Diag:B
PH8-2100-200
1*Lamp Type: GPHA1000T6 GPHA843T6
Wiring Diag:A
Technical specifications
Mains Voltage:110-240VAC±10%
Mains Frequency:50/60Hz
Power Factor: >0.98
Efficiency: >92%
Operating Frequency: 40-60KHz
Dimensions: 250*65*40mm
Lamp status indication via LED indication
Green LED:Lamp on
Red LED:Lamp fault
Lamp status forwarding
Potential free relay contacts for lamp on/lamp fault..
Installation requirement
Wire Gauge:0.5-1.5mm2
Max.cable length between ballasts and lamp:5m
Relay contacts:potential free,load:50…500mA at 24…230V AC;
50…500mA at 5…60V DC
DC5V±5% 5mA:lamp on. DC 0V:lamp fault or on lamp. Connect LED.
DC5V±10% Max 50mA:lamp on. DC 0V:lamp fault or on lamp. Connect Relay.
Mounting restrictions
Disconnect Input Power Before Installing or Servicing.
Ballast Case Must Be Grounded.
Don’t short any two wires of the four outputs.
Features
Starting:Preheat
Applications
All areas of applications includes UV lamps
Air purification
Industrial water treatment
Municipal water treatment
Type | Input Voltage(V) | Input Power (W) | Input Current (A) | Power Per Lamp(W) | Lamp Current(A) | Weight (kg) | Packing(mm) | Qty(pcs) | GW(kg) |
PH8-800-155 | 99-264 | 168 | 1.53A@110V | 55~155 | 0.75-0.85 | 0.53 | 450*280*190 | 18 | 10 |
0.70A@240V | |||||||||
PH8-1200-190 | 99-264 | 206 | 1.87A@110V | 42-190 | 1.1-1.3 | 0.53 | 450*280*190 | 18 | 10 |
0.85A@240V | |||||||||
PH8-1500-150 | 99-264 | 164 | 1.50A@110V | Oct-57 | 1.4-1.6 | 0.53 | 450*280*190 | 18 | 10 |
0.68A@240V | |||||||||
PH8-1800-150 | 99-264 | 164 | 1.50A@110V | 65-150 | 1.7-1.9 | 0.53 | 450*280*190 | 18 | 10 |
0.68A@240V | |||||||||
PH8-2100-200 | 99-264 | 217 | 1.98A@110V | 200 | 2.0-2.2 | 0.53 | 450*280*190 | 18 | 10 |
0.90A@240V |